Optran® HUV, Optran® HWF
Hard Polymer-Clad Fiber - Cleave N Connect™
Features
Applications
Properties
Specifications
Notes
Click here to view the data sheet in PDF format:
Optran HUV, Optran HWF
Optran HUV and Optran HWF hard polymer-clad fibers offer high numerical apertures to suit a broad range of applications, from remote illumination to photodynamic therapy. This high quality fiber offers easy termination with no pistoning effect and is a cost effective alternative to silica/silica fiber. We offer a choice of several jacket types and sizes - as well as custom-designed products and sizes to meet your specifications.
 
Features
- High numerical apertures (0.37, 0.48)High fiber strengthReduced static fatigueLower microbend lossesBiocompatible materialsSterilizable by ETO and other methodsManufactured at GMP and ISO 9001 compliant facilityRadiation resistantHigh concentricityCost effective (compared to silica/silica fibers)
- Easy termination with no pistoning effect
Applications
Medical
- Medical diagnosticsLaser delivery
- Photodynamic therapy
Industrial / Scientific
- SpectroscopyRemote illuminationSensorsLaser welding / soldering / markingLaser deliveryThomson scatteringUV photolithographyNuclear plasma diagnosticsAnalytical instrumentsLaser diode pigtailingPyrometry
- Semiconductor capital equipment
Properties
- Pure silica coreProprietary bonded hard polymer claddingStep index profile
- Numerical aperture: 0.37 (standard) or 0.48 (high) ± 0.02
- Broad spectral range:
- Optran HUV: 300 - 1200 nm
- Optran HWF: 400 - 2200 nm
- Standard prooftest: 70 kpsi
- Bend radius:
Momentary - 100 x core radius
Long term - 300 x core radius
Specifications
| Product Code – UV |
ØCore (µm) ±2% |
ØClad (µm) ±2% |
ØJacket (µm) ±5% |
| HUV 125/140 T |
125 |
140 |
400* |
| HUV 200/230 T |
200 |
230 |
500 |
| HUV 300/330 T |
300 |
330 |
650 |
| HUV 400/430 T |
400 |
430 |
730 |
| HUV 600/630 T |
600 |
630 |
1040 |
| HUV 800/830 T |
800 |
830 |
1040 |
| HUV 1000/1035 T |
1000 |
1035 |
1400 |
| HUV 1500/1550 T |
1500 |
1550 |
2000 |
| Product Code – WF |
ØCore (µm) ±2% |
ØClad (µm) ±2% |
ØJacket (µm) ±5% |
| HWF 125/140 T |
125 |
140 |
400* |
| HWF 200/230 T |
200 |
230 |
500 |
| HWF 300/330 T |
300 |
330 |
650 |
| HWF 400/430 T |
400 |
430 |
730 |
| HWF 600/630 T |
600 |
630 |
1040 |
| HWF 800/830 T |
800 |
830 |
1040 |
| HWF 1000/1035 T |
1000 |
1035 |
1400 |
| HWF 1500/1550 T |
1500 |
1550 |
2000 |
Suffix product code with "48" to indicate high (0.48) NA. Example: HUV 600/660 T 48
Notes
*Core / Clad ratio may not support transmission for long wavelengths.
Because attenuation may vary below 400 nm, Optran HUV is not recommended for use below this wavelength.
Other sizes available.
Upon request, pure silica core can be substituted with a quartz/quartz structure, providing an all silica fiber with a standard numerical aperture of 0.22.
NA is measured at the 95% intensity angle.
Tefzel® jacket can be omitted upon request. Tefzel® is a registered DuPont product.
CeramOptec strives to ensure the accuracy of all information provided; however, we imply no warranties and disclaim any liability in connection with the use of this information.
©2003 CeramOptec Industries, Inc. |